A single Tonerider Rebel 90 through one 500kA volume to a mono jack. Tonerider draws it for all its Rebel 90 pickups.

One Rebel 90 and one volumeOne Rebel 90 and one volume: One Rebel 90 · One volume. Original Tinkercaster drawing with labelled terminals.Rebel 90Rebel 90Volume 500kA · 500k500kOutput jackBridge groundwhiteblacklug1lug2lug3tipsleeveground

Viewed from the back of the controls, as you solder them. Open the interactive diagram to zoom, move components and try the switches.

Parts and values

In the drawingValuePart
Rebel 90Source: Rebel 90 (all Rebel 90 pickups)—Single-coil pickup (two-conductor)Generic
Volume 500kA500kCTS 500k Audio PotExample part
Output jackSource: Output Jack—Switchcraft #11Example part
Bridge groundSource: Ground Wire from Bridge—Bridge ground wireGeneric

“Example part” means any part with the same value and lugs will do; the source does not name a brand. “Generic” stands in for an unspecified pickup: check your own pickup's lead colours before you solder.

Specific to this wiring

  • The pickup cable carries a white lead, a black lead and a bare shield wire.
  • The white lead goes to the volume's left lug; the black lead and the bare shield wire both end on the upper-left solder spot on the volume casing.
  • The volume's right lug is linked to its casing with a short black wire.
  • The source labels the jack wires: 'Signal/Hot Wire to Output Jack Tip Lug' from the volume's middle lug, and 'Ground Wire to Output Jack Sleeve Lug' from the volume casing.
  • The 'Ground Wire from Bridge' ends on the right-hand solder spot on the volume casing, the same spot as the jack ground wire.

Connections

In soldering order: grounds first, then the switch, the pickups and the signal path.

#FromToHow
1Rebel 90 blackVolume casingUpper-left solder spot.To a pot casingblack
2Rebel 90 bare shieldVolume casingBare Shield Wire, to the same upper-left solder spot.Shield or groundbare
3Volume right lugVolume casingTo a pot casingblack
4Volume casingJack sleeveGround Wire to Output Jack Sleeve Lug, from the right-hand solder spot.To a pot casing
5Bridge groundVolume casingGround Wire from Bridge, to the right-hand solder spot.Shield or ground
6Rebel 90 whiteVolume left lug (input)Wirewhite
7Volume middle lugJack tipSignal/Hot Wire to Output Jack Tip Lug.Wire

What each position does

SettingThe sourceEngine result
1Single pickup.Rebel 90.

Checked with the Tinkercaster wiring engine against the switching the source describes.

  • The Rebel 90 is simulated as a generic two-conductor single coil; hum and phase describe that generic model, not the Rebel 90.
  • Pickup resistance is not specified, so no numeric meter readings are given.

Before you solder

Ticks are kept in this browser only, as a reminder. They are not a check of your joints. New to soldering? Read the soldering cheat sheet.

Check before plugging in

  • With the volume up, the meter across the jack should read the pickup's resistance.
  • The volume casing, the jack sleeve and the bridge ground should all read continuous with each other.

Measure across the output jack with a multimeter on its resistance range. No exact readings are given where the source does not specify the pickups.