Tonerider wiring

One P90, volume and tone

One P90 · Volume · Tone

Transcribed from the manufacturer wiring sheet and checked against the engine.

Viewed from the back of the controls, as you solder them.

One P90, volume and toneOne P90, volume and tone: One P90 · Volume · Tone. Original Tinkercaster drawing with labelled terminals.P90500k500k22nFwhiteblackbarelug1lug2lug3lug1lug2lug3abtipsleevegroundP90Volume 500kATone 500kA.022µfOutput jackBridge ground

Open the interactive diagram to zoom, move components and try the switches.

Parts and values

In the drawingValuePart
P90—Tonerider Hot 90Example part
Volume 500kA500kCTS 500k Audio PotExample part
Tone 500kA500kCTS 500k Audio PotExample part
.022µf22nFOrange Drop .022µFExample part
Output jack—Switchcraft #11Example part
Bridge ground—Bridge ground wireGeneric

Every pickup is the maker's own. “As specified” means the sheet names that part. “Example part” means the sheet names no model: the pickup shown is one of the maker's with the same leads, and any pot, cap or switch with the same value and lugs will do. “Generic” is a plain part such as a ground wire. “Not on the sheet; stand-in” means the sheet prints no value for that part, so the value shown is the usual one, not the maker's.

Connections

In soldering order: grounds first, then the switch, the pickups and the signal path.

#FromToHow
1P90 black lead and Bare Shield Wire both end on the volume casing.P90 black lead and Bare Shield Wire both end on the volume casing.Wireblack
2Volume right lug is bent onto the casing.Volume right lug is bent onto the casing.Wireground
3Tone right lug is bent onto the tone casing.Tone right lug is bent onto the tone casing.Wireground
4Tone casing links to the volume casing.Tone casing links to the volume casing.Wireground
5Jack sleeve is grounded (sheet ground symbol).Jack sleeve is grounded (sheet ground symbol).Wireground
6Ground Wire from Bridge ends on the volume casing.Ground Wire from Bridge ends on the volume casing.Wireground
7P90 bare shieldP90 black lead and Bare Shield Wire both end on the volume casing.Shield or groundbare
8P90 white lead goes to the volume's left lug.P90 white lead goes to the volume's left lug.Wirewhite
9Volume middle lug runs to the jack tip.Volume middle lug runs to the jack tip.Wiresignal
10One leg of the .022µf capacitor goes to the volume's left lug.One leg of the .022µf capacitor goes to the volume's left lug.Wiresignal
11The other leg of the .022µf capacitor goes to the tone's middle lug.The other leg of the .022µf capacitor goes to the tone's middle lug.Wiresignal

What it does

Engine result: P90.

Checked with the Tinkercaster wiring engine against the switching the source describes.

Before you solder

Ticks are kept in this browser only, as a reminder. They are not a check of your joints. New to soldering? Read the soldering cheat sheet .

Check before plugging in

    Measure across the output jack with a multimeter on its resistance range. No exact readings are given where the source does not specify the pickups.