Tonerider wiring

Two humbuckers toggle two push-pull volumes two tones

Two humbuckers toggle two push-pull volumes two tones

Two humbuckers toggle two push-pull volumes two tones. Transcribed from the manufacturer wiring sheet and checked against the engine.

Two humbuckers toggle two push-pull volumes two tonesTwo humbuckers toggle two push-pull volumes two tones: Two humbuckers toggle two push-pull volumes two tones. Original Tinkercaster drawing with labelled terminals.Neck PickupNeck PickupBridge PickupBridge Pickup3-Way ToggleNeck Volume 500kA push/pull · 500k500kBridge Volume 500kA push/pull · 500k500kNeck Tone 500kA · 500k500kBridge Tone 500kA · 500k500kOutput Jack.022µf (neck) · 22nF22nF.022µf (bridge) · 22nF22nFGround wire from bridgeredgreenblackwhitebareredgreenblackwhitebareT1T2T3T4lug1lug2lug3sw1sw2sw3sw4sw5sw6lug1lug2lug3sw1sw2sw3sw4sw5sw6lug1lug2lug3lug1lug2lug3tipsleeveababground

Viewed from the back of the controls, as you solder them. Open the interactive diagram to zoom, move components and try the switches.

Parts and values

In the drawingValuePart
Neck Pickup—Humbucker (four-conductor, DiMarzio colours)Generic
Bridge Pickup—Humbucker (four-conductor, DiMarzio colours)Generic
3-Way Toggle—Switchcraft 3-Way ToggleExample part
Neck Volume 500kA push/pull500k500k Push-Pull DPDTExample part
Bridge Volume 500kA push/pull500k500k Push-Pull DPDTExample part
Neck Tone 500kA500kCTS 500k Audio PotExample part
Bridge Tone 500kA500kCTS 500k Audio PotExample part
Output Jack—Switchcraft #11Example part
.022µf (neck)22nFOrange Drop .022µFExample part
.022µf (bridge)22nFOrange Drop .022µFExample part
Ground wire from bridge—Bridge ground wireGeneric

“Example part” means any part with the same value and lugs will do; the source does not name a brand. “Generic” stands in for an unspecified pickup: check your own pickup's lead colours before you solder.

Specific to this wiring

  • Capacitor-before-pot tones; each volume push/pull splits its pickup.
  • Neck lead colours mapped by function onto DiMarzio-style four-conductor catalog part.

Connections

In soldering order: grounds first, then the switch, the pickups and the signal path.

#FromToHow
1Neck Pickup gndNeck Volume 500kA push/pull casingWireblack
2Neck Pickup bareNeck Volume 500kA push/pull casingWirebare
3Bridge Pickup gndBridge Volume 500kA push/pull casingWiregreen
4Bridge Pickup bareBridge Volume 500kA push/pull casingWirebare
5Neck Volume 500kA push/pull sw1Neck Volume 500kA push/pull casingWireblack
6Bridge Volume 500kA push/pull sw1Bridge Volume 500kA push/pull casingWireblack
7Neck Volume 500kA push/pull lug1Neck Volume 500kA push/pull casingWireground
8Bridge Volume 500kA push/pull lug1Bridge Volume 500kA push/pull casingWireground
9Neck Tone 500kA lug1Neck Tone 500kA casingWireground
10Bridge Tone 500kA lug1Bridge Tone 500kA casingWireground
113-Way Toggle T4Neck Volume 500kA push/pull casingWireground
12Output Jack sleeveNeck Volume 500kA push/pull casingWireground
13Bridge Volume 500kA push/pull casingNeck Volume 500kA push/pull casingWireground
14Neck Tone 500kA casingNeck Volume 500kA push/pull casingWireground
15Bridge Tone 500kA casingNeck Volume 500kA push/pull casingWireground
16Ground wire from bridge groundNeck Volume 500kA push/pull casingWireground
17Neck Volume 500kA push/pull lug23-Way Toggle T1Wiresignal
18Bridge Volume 500kA push/pull lug23-Way Toggle T2Wiresignal
193-Way Toggle T3Output Jack tipWiresignal
20Neck Pickup hotNeck Volume 500kA push/pull lug3Wirewhite
21Neck Pickup blackNeck Volume 500kA push/pull sw2Wiregreen
22Neck Pickup whiteNeck Volume 500kA push/pull sw2Wirered
23Bridge Pickup hotBridge Volume 500kA push/pull lug3Wirered
24Bridge Pickup whiteBridge Volume 500kA push/pull sw2Wirewhite
25Bridge Pickup blackBridge Volume 500kA push/pull sw2Wireblack
26Neck Volume 500kA push/pull lug3.022µf (neck) aWiresignal
27.022µf (neck) bNeck Tone 500kA lug2Wiresignal
28Bridge Volume 500kA push/pull lug3.022µf (bridge) aWiresignal
29.022µf (bridge) bBridge Tone 500kA lug2Wiresignal

What each position does

SettingThe sourceEngine result
Position 1; p4=down, p5=downEngine reading of the transcribed board; matches the source legend.Neck Pickup (both coils).
Position 1; p4=down, p5=upEngine reading of the transcribed board; matches the source legend.Neck Pickup (both coils).
Position 1; p4=up, p5=downEngine reading of the transcribed board; matches the source legend.Neck Pickup (split to one coil).
Position 1; p4=up, p5=upEngine reading of the transcribed board; matches the source legend.Neck Pickup (split to one coil).
Position 2; p4=down, p5=downEngine reading of the transcribed board; matches the source legend.Neck Pickup (both coils) and Bridge Pickup (both coils) in parallel.
Position 2; p4=down, p5=upEngine reading of the transcribed board; matches the source legend.Neck Pickup (both coils) and Bridge Pickup (split to one coil) in parallel.
Position 2; p4=up, p5=downEngine reading of the transcribed board; matches the source legend.Neck Pickup (split to one coil) and Bridge Pickup (both coils) in parallel.
Position 2; p4=up, p5=upEngine reading of the transcribed board; matches the source legend.Neck Pickup (split to one coil) and Bridge Pickup (split to one coil) in parallel.
Position 3; p4=down, p5=downEngine reading of the transcribed board; matches the source legend.Bridge Pickup (both coils).
Position 3; p4=down, p5=upEngine reading of the transcribed board; matches the source legend.Bridge Pickup (split to one coil).
Position 3; p4=up, p5=downEngine reading of the transcribed board; matches the source legend.Bridge Pickup (both coils).
Position 3; p4=up, p5=upEngine reading of the transcribed board; matches the source legend.Bridge Pickup (split to one coil).

Checked with the Tinkercaster wiring engine against the switching the source describes.

  • Custom-taper pots are treated as linear by the simulator.

Before you solder

Ticks are kept in this browser only, as a reminder. They are not a check of your joints. New to soldering? Read the soldering cheat sheet.

Check before plugging in

    Measure across the output jack with a multimeter on its resistance range. No exact readings are given where the source does not specify the pickups.