Skip to content
Tinkercaster

Seymour Duncan wiring

Two P-Rails, toggle, volume and tone push/pull splits

2 P-Rails · toggle · 1V · 1T · push/pull splits

Transcribed from the manufacturer wiring sheet.

Viewed from the back of the controls, as you solder them.

Two P-Rails, toggle, volume and tone push/pull splitsTwo P-Rails, toggle, volume and tone push/pull splits: 2 P-Rails · toggle · 1V · 1T · push/pull splits. Original Tinkercaster drawing with labelled terminals.Neck pickupBridge pickup500k500k47nFblackgreenwhiteredbareblackgreenwhiteredbareT1T2T3T4lug1lug2lug3sw1sw2sw3sw4sw5sw6tipsleevegroundlug1lug2lug3sw1sw2sw3sw4sw5sw6abNeck pickupBridge pickup3-way toggleVolume 500k push/pullOutput jackBridge groundTone 500k push/pull.047 cap · 47nF

Open the interactive diagram to zoom, move components and try the switches.

Parts and values

In the drawingValuePart
Neck pickup—Seymour Duncan P-RailsAs specified
Bridge pickup—Seymour Duncan P-RailsAs specified
3-way toggle—Switchcraft 3-Way ToggleExample part
Volume 500k push/pull500k500k Push-Pull DPDTExample part
Output jack—Switchcraft #11Example part
Bridge ground—Bridge ground wireGeneric
Tone 500k push/pull500k500k Push-Pull DPDTExample part
.047 cap47nFOrange Drop .047µFExample part

Every pickup is the maker's own. “As specified” means the sheet names that part. “Example part” means the sheet names no model: the pickup shown is one of the maker's with the same leads, and any pot, cap or switch with the same value and lugs will do. “Generic” is a plain part such as a ground wire. “Not on the sheet; stand-in” means the sheet prints no value for that part, so the value shown is the usual one, not the maker's.

Understand this wiring

All Seymour Duncan wiring guides →

Connections

In soldering order: grounds first, then the switch, the pickups and the signal path.

#FromToHow
1Neck pickup gndTone 500k push/pull sw1Wiregreen
2Neck pickup bareTone 500k push/pull casingWirebare
3Bridge pickup gndTone 500k push/pull sw4Wiregreen
4Bridge pickup bareVolume 500k push/pull casingWirebare
5Volume 500k push/pull lug1Volume 500k push/pull casingWireground
63-way toggle T4Volume 500k push/pull casingWireground
7.047 cap bTone 500k push/pull casingWireblack
8Tone 500k push/pull sw1Tone 500k push/pull sw4Wireground
9Tone 500k push/pull sw1Tone 500k push/pull casingWireground
10Tone 500k push/pull casingOutput jack sleeveWireground
11Bridge ground groundVolume 500k push/pull casingWireground
12Volume 500k push/pull casingTone 500k push/pull casingWireground
13Neck pickup hot3-way toggle T1Wireblack
14Bridge pickup hot3-way toggle T2Wireblack
153-way toggle T3Volume 500k push/pull lug3Wiresignal
16Neck pickup whiteTone 500k push/pull sw2Wirewhite
17Neck pickup redVolume 500k push/pull sw2Wirered
18Bridge pickup whiteTone 500k push/pull sw5Wirewhite
19Bridge pickup redVolume 500k push/pull sw5Wirered
20Volume 500k push/pull sw1Neck pickup hotWireblack
21Volume 500k push/pull sw4Bridge pickup hotWireblack
22Volume 500k push/pull lug3Tone 500k push/pull lug1Wireblack
23Volume 500k push/pull lug2Output jack tipWiresignal
24Tone 500k push/pull lug2.047 cap aWireblack
25Volume 500k push/pull sw3Tone 500k push/pull sw3Coil-split joint: volume and tone down contacts meet here.Wireblack
26Volume 500k push/pull sw6Tone 500k push/pull sw6Coil-split joint: volume and tone down contacts meet here for the bridge pickup.Wireblack

What each position does

SettingThe sourceEngine result
Position 1 Neck: Parallel (both coils on)Engine reading of the transcribed board; matches the source sheet's table.Neck pickup (coils in parallel).
Position 1 Neck: P-90 coils selected (rails shut off)Engine reading of the transcribed board; matches the source sheet's table.Neck pickup (split to one coil).
Position 1 Neck: Rail coils selected (P-90s shut off)Engine reading of the transcribed board; matches the source sheet's table.Neck pickup (split to one coil).
Position 1 Neck: Series (both coils on)Engine reading of the transcribed board; matches the source sheet's table.Neck pickup (both coils).
Position 2 Neck + bridge: Parallel (both coils on)Engine reading of the transcribed board; matches the source sheet's table.Neck pickup (coils in parallel) and Bridge pickup (coils in parallel) in parallel.
Position 2 Neck + bridge: P-90 coils selected (rails shut off)Engine reading of the transcribed board; matches the source sheet's table.Neck pickup (split to one coil) and Bridge pickup (split to one coil) in parallel.
Position 2 Neck + bridge: Rail coils selected (P-90s shut off)Engine reading of the transcribed board; matches the source sheet's table.Neck pickup (split to one coil) and Bridge pickup (split to one coil) in parallel.
Position 2 Neck + bridge: Series (both coils on)Engine reading of the transcribed board; matches the source sheet's table.Neck pickup (both coils) and Bridge pickup (both coils) in parallel.
Position 3 Bridge: Parallel (both coils on)Engine reading of the transcribed board; matches the source sheet's table.Bridge pickup (coils in parallel).
Position 3 Bridge: P-90 coils selected (rails shut off)Engine reading of the transcribed board; matches the source sheet's table.Bridge pickup (split to one coil).
Position 3 Bridge: Rail coils selected (P-90s shut off)Engine reading of the transcribed board; matches the source sheet's table.Bridge pickup (split to one coil).
Position 3 Bridge: Series (both coils on)Engine reading of the transcribed board; matches the source sheet's table.Bridge pickup (both coils).

Checked with the Tinkercaster wiring engine against the switching the source describes.

  • Coil split is topology-first; the P-90 and rail positions share one coil mode in the engine.

Before you solder

Ticks are kept in this browser only, as a reminder. They are not a check of your joints. New to soldering? Read the soldering cheat sheet .

Check before plugging in

    Measure across the output jack with a multimeter on its resistance range. No exact readings are given where the source does not specify the pickups.